REVIEW:
NEC PA241W
Part 15
|
Comparison with the AdobeRGB working colour space with regard to the monitor profile
| Parameter |
Target |
Measured |
| White point / CCT Kelvin |
D65 (6502) |
6575 |
| White point XYZ (normalised) |
95.04 100.00 108.88 |
95.06 100.00 109.98 |
| DeltaE from target white point |
- |
0,67 |
| DeltaE from black body curve* |
- (0,08) |
0,14 |
| Luminance / cd/m² |
140 |
139,4 |
| Black point / cd/m² |
Native |
0,21 |
| Contrast / x:1 |
Native |
663 |
| Gradation / average |
Gamma 2.2 |
~2,17 (avg.) |
* CCT reference
Advertisement
Comparison with the ECI-RGB 2.0 working colour space with regard to the monitor profile
| Parameter |
Target |
Measured |
| White point / CCT Kelvin |
D5o (5002) |
5073 |
| White point XYZ (normalised) |
96.42 100.00 82.51 |
96.14 100.00 83.62 |
| DeltaE from target white point |
- |
1,01 |
| DeltaE from black body curve* |
- (0,07) |
0,29 |
| Luminance / cd/m² |
140 |
140,3 |
| Black point / cd/m² |
Native |
0,27 |
| Contrast / x:1 |
Native |
519 |
| Gradation / average |
L* |
L* |
* CCT reference
|
No Comments available
go to the forum!