Thus, including dynamic contrast (except a better value than black 0,06 cd/m2) HCFR showed a large deviation from the D65 centre with very large deltaE values. In any case do not use this option regardless of what gives better blacks.
Advertisement
RGB values can be viewed in the following graphs:
Graph before calibration.
Graph after calibration.
It is important to note that deltaE on 70IRE is at 4 which is a solid result!
Gamma
Graph before calibration.
Graph after calibration.
Given that the Philips 42PFL8404H does not have the possibility to regulate gamma values, we only had a small possibility to influence this value, which is quite uniform in the "standard" mode. After calibration, we only raised the lowest point on 50% brightness, but in general there were no significant changes.
Brightness
Graph before calibration.
Even in "normal" mode, brightness was extremely good, and the results of our measurements showed almost perfect tracking of the reference line, we see a mild discrepancy in brightness from 30 to 60%. Let’s see if we can make it any better.